Suitable for most twisted pair signalling applications.
Available for working voltages of up to 6, 15, 30 and 50 volts and telephone pairs with a maximum working or ringing voltage of 190 volts.
Derivatives of these protectors are available, ready-boxed to IP66, for use in damp or dirty environments - click here. If your system requires a protector with a very low resistance.
Application
Use on twisted pair lines to protect connected equipment from transient overvoltage damage. Typical uses include the protection of:
process control equipment
telemetry and SCADA
modems
computer communications interfaces
Features and benefits
Low let-through voltage restricts transient voltages to a safe level to ensure maximum protection for your systems.
Protection between all lines closes all transient paths to equipment for complete protection.
Provides repeated protection in lightning intense environments.
Low in-line resistance minimises unnecessary reductions in signal strength.
Strong, flame retardant, ABS housing.
Supplied ready for flat mounting on base or side.
Built-in DIN rail foot for simple clip-on mounting to top hat DIN rails.
Colour coded terminals give a quick and easy installation check - grey for the dirty (line) end and green for the clean end.
Screen terminal enables easy connection of cable screen to earth.
Substantial earth stud to enable effective earthing.
Integral earthing plate enables enhanced connection to earth via CME kit.
Straightforward, comprehensive installation instructions.
UK Oftel Approval NS/G/1235/W/100025.
5 year warranty.
Installation
Connect in series with the data communication or signal line either near where it enters or leaves the building or close to the equipment being protected (eg. within its control panel). Either way it must be very close to the systems earth star point. Install protectors either within an existing cabinet/cubicle or in a separate enclosure.
Suitable accessories
Simultaneously mount and earth up to 4 of these protectors on a CME 4, up to 8 on a CME 8, up to 16 on a CME 16, or up to 32 on a CME 32 .
Where Lightning Barriers cannot be incorporated within an existing panel or enclosure, WBX enclosures are available for a CME 4 and its associated protectors (WBX 4), CME 8 and protectors (WBX 8) or one or two CME 16 kits and protectors (WBX 16/2/G).
Electrical specification
ESP 06D |
ESP 15D |
ESP 30D |
ESP 50D |
ESP TN | |
Nominal voltage¹ |
6V |
15V |
30V |
50V |
* |
Maximum working voltage² |
7.79V |
19V |
37.1V |
58V |
190V |
Current rating (signal) |
300mA |
300mA |
300mA |
300mA |
300mA |
In-line resistance (per line ± 10%) |
9.4ohm |
9.4ohm |
9.4ohm |
9.4ohm |
4.4ohm |
Bandwidth (-3dB 50ohm system) |
800kHz |
2.5MHz |
4MHz |
6MHz |
>50MHz |
1 Nominal voltage (DC or AC peak) measured at <5µA (ESP 15D, ESP 30D, ESP 50D) and <200µA (ESP 06D).
2 Maximum working voltage (DC or AC peak) measured at <1mA leakage (ESP 15D, ESP 30D, ESP 50D), <10mA (ESP 06D) and <95µA (ESP TN).
* Post transient recovery voltage >80V.
Transient specification
ESP 06D |
ESP 15D |
ESP 30D |
ESP 50D |
ESP TN | |
Let-through voltage (all conductors)¹ 5kV, 10/700µs test to: BS6651:1999 Appendix C, Cat C-High ITU (formerly CCITT) IX K17 |
10.5V |
23.8V |
43.4V |
74.9V |
200V |
Maximum surge current² -per signal wire -per pair |
10kA 20kA |
10kA 20kA |
10kA 20kA |
10kA 20kA |
10kA 20kA |
1 The maximum transient voltage let-through the protector throughout the test (+/-10%), line to line & line to earth. Response time <10ns.
2 Tested with 8/20µs waveshape to ITU (formely CCITT), BS 6651:1999 Appendix C.
Mechanical specification
ESP 06D |
ESP 15D |
ESP 30D |
ESP 50D |
ESP TN | |
Temperature range |
-25°C to +70°C |
-25°C to +70°C |
-25°C to +70°C |
-25°C to +70°C |
-25°C to +70°C |
Connection type |
Screw terminal |
Screw terminal |
Screw terminal |
Screw terminal |
Screw terminal |
Connection size (stranded |
1.5mm² |
1.5mm² |
1.5mm² |
1.5mm² |
1.5mm² |
Earth connection |
M6 stud |
M6 stud |
M6 stud |
M6 stud |
M6 stud |
Weight -unit -packaged (per 10) |
0.08kg 0.85kg |
0.08kg 0.85kg |
0.08kg 0.85kg |
0.08kg 0.85kg |
0.08kg 0.85kg |
Dimensions |
![]() |
Download: