Lightning Protection Products

ZoneMaster_ZM11200、ZM11201、ZM11202、ZM11203、ZM11204、ZM11206、ZM11207、ZM11208、ZM11300、ZM11301、ZM11302、ZM11303、ZM11304、ZM11306、ZM11307、ZM11308


Product No:Pro20096511838
Product Model:ZM11200、ZM11201、ZM11202、ZM11203、ZM11204、ZM11206、ZM11
UpdateTime:
Views:1153

Details:


Features
Enhanced redundancy built into each module
Easy to read status indication
Thermal and short circuit fusing
Low let-through performance with high current impulses
100k AIC short circuit current rating
 Replaceable bolt-in modules
Large block MOV technology
UL 1449 3rd Edition
15 year product warranty

Optional Features
 High performance UL 1283 EMI/RFI fi lter
 Flush mount capability
 Remote monitoring unit

Specifi cations
Maximum continuous operating voltage
120V — 140Vac
240V — 280Vac
277V — 320Vac
Lines protected
ZoneMaster 170
L-N 170kA, L-L 170kA, N-G 170kA
ZoneMaster 200
L-N 200kA, L-L 200kA, N-G 200kA
Duty cycle performance (8/20μs)
100,000A >4 impulses
10,000A >8,000 impulses
170A infi nite
Impulse current for class I (Iimp)
50kA (10/350μs)
Long duration current pulse
(10/1,000μs) capability
3,600A (tested)
Ambient temperature limits
-40°F to +185°F (working)
-40°C to +85°C (working)
Humidity
95% RH (non-condensing)
Enclosure
NEMA 1, 2, 3, 3S, 4, 4X, 12 & 13 (IP66)
Terminals
2 AWG (32mm2)
Mounting
Surface mount by 0.31” (8mm)
diameter holes
Indication
Continuous visual status monitoring
Green LED Lit = Full protection
Red LED Lit = Reduced (Standby) OR
No protection
Green LED out = No power to protector
Red & Green LED Lit = High N-G voltage
Remote contacts
NO/NC
Weight
Approx. 7 lbs (3.2 kg)
Dimensions
Enclosure — see fi gure 1
EMC compliance
BS EN 60950: 1992
BS EN 61000-6-2: 1999
Optional Power Filter
Limiting voltage
200V (@ 3kA 8/20μs)
Maximum attenuation (typical)
-75dB (100kHZ to 100MHz)
To order specify -
Model number as per specifi cation table
Add suffi x X for EMI/RFI fi lter
Add suffi x F for fl ush mount options
Optional Remote Monitoring
Unit
ZM11101 — Battery operated
ZM11102 — AC powered

Model Maximum surge current Imax (kA) Working voltage (V) UL SVR 2nd Edition (V) UL VPR 3rd Edition (V) Limiting voltage Phase types
    @ 3kA (V) @10kA (In) (V)
ZM11200 170 120/240 split 400 600 350 446 Split phase 3 wire
ZM11201 170 120/208 400 600 350 446 Three phase 4 wire WYE
ZM11202 170 120/240 400/800 600/1000 350 446 Three phase 4 wire Delta
ZM11203 170 240 800 1000 760 886 Three phase 3 wire Delta
ZM11204 170 277/480 800 1000 760 886 Three phase 4 wire WY
ZM11206 170 480 1200 1800 1480 1680 Three phase 3 wire Delta
ZM11207 170 220/380 800 1000 760 886 Three phase 4 wire WYE
ZM11208 170 240/415 800 1000 760 886 Three phase 4 wire WYE
ZM11300 200 120/240 split —— 600 350 446 Split phase 3 wire
ZM11301 200 120/208 —— 600 350 446 Three phase 4 wire WYE
ZM11302 200 120/240 —— 600/1000 350 446 Three phase 4 wire Delta
ZM11303 200 240 —— 1000 760 886 Three phase 3 wire Delta
ZM11304 200 277/480 —— 1000 760 886 Three phase 4 wire WYE
ZM11306 200 480 —— 1800 1480 1680 Three phase 3 wire Delta
ZM11307 200 220/380 —— 1000 760 886 Three phase 4 wire WYE
ZM11308 200 240/415 —— 1000 760 886 Three phase 4 wire WYE

Download:


  ZoneMaster.pdf