Lightning Protection Products

DEHNguard S FM

Product No:Pro200964103411
Product Model:DEHNguard S FM
UpdateTime:
Views:556

Details:

DEHNguard S FM
DEHNguard S ... FM Dimension drawing DG S ... FM Basic circuit diagram DG S ... FM
DG S ... FM: Single-pole pluggable surge arrester consisting of a base part and plug-in protection module; with floating remote signalling contact
DG S 48 FM | DG S 75 FM | DG S 150 FM | DG S 275 FM | DG S 320 FM | DG S 385 FM | DG S 440 FM | DG S 600 FM | |
SPD according to EN 61643-11 | Type 2 | Type 2 | Type 2 | Type 2 | Type 2 | Type 2 | Type 2 | Type 2 |
SPD according to IEC 61643-1 | Class II | Class II | Class II | Class II | Class II | Class II | Class II | Class II |
Max. continuous operating a.c. voltage [UC] | 48 V | 75 V | 150 V | 275 V | 320 V | 385 V | 440 V | 600 V |
Max. continuous operating d.c. voltage [UC] | 60 V | 100 V | 200 V | 350 V | 420 V | 500 V | 585 V | 600 V |
Nominal discharge current (8/20 µs) [In] | 10 kA | 10 kA | 15 kA | 20 kA | 20 kA | 20 kA | 20 kA | 15 kA |
Max. discharge current (8/20 µs) [Imax] | 25 kA | 40 kA | 40 kA | 40 kA | 40 kA | 40 kA | 40 kA | 30 kA |
Voltage protection level [UP] | ≤ 0.3 kV | ≤ 0.4 kV | ≤ 0.7 kV | ≤ 1.25 kV | ≤ 1.5 kV | ≤ 1.75 kV | ≤ 2 kV | ≤ 2.5 kV |
Voltage protection level for 5 kA [UP] | ≤ 0.25 kV | ≤ 0.35 kV | ≤ 0.55 kV | ≤ 1 kV | ≤ 1.2 kV | ≤ 1.35 kV | ≤ 1.7 kV | ≤ 2 kV |
Response time [tA] | ≤ 25 ns | ≤ 25 ns | ≤ 25 ns | ≤ 25 ns | ≤ 25 ns | ≤ 25 ns | ≤ 25 ns | ≤ 25 ns |
Max. mains-side overcurrent protection | 125 A gL/gG | 125 A gL/gG | 125 A gL/gG | 125 A gL/gG | 125 A gL/gG | 125 A gL/gG | 125 A gL/gG | 100 A gL/gG |
Short circuit withstand capability for max. mains-side overcurrent protection | 50 kArms | 50 kArms | 50 kArms | 50 kArms | 25 kArms | 25 kArms | 25 kArms | 25 kArms |
Temporary overvoltage (TOV) [UT] | -- | -- | -- | 335 V / 5 sec. | 335 V / 5 sec. | -- | 580 V / 5 sec. | -- |
Operating temperature range [TU] | -40°C...+80°C | -40°C...+80°C | -40°C...+80°C | -40°C...+80°C | -40°C...+80°C | -40°C...+80°C | -40°C...+80°C | -40°C...+80°C |
Operating state/fault indication | green / red | green / red | green / red | green / red | green / red | green / red | green / red | green / red |
Cross-sectional area (min.) | 1.5 mm2solid/flexible | 1.5 mm2solid/flexible | 1.5 mm2solid/flexible | 1.5 mm2solid/flexible | 1.5 mm2solid/flexible | 1.5 mm2solid/flexible | 1.5 mm2solid/flexible | 1.5 mm2solid/flexible |
Cross-sectional area (max.) | 35 mm2stranded/25 mm2flexible | 35 mm2stranded/25 mm2flexible | 35 mm2stranded/25 mm2flexible | 35 mm2stranded/25 mm2flexible | 35 mm2stranded/25 mm2flexible | 35 mm2stranded/25 mm2flexible | 35 mm2stranded/25 mm2flexible | 35 mm2stranded/25 mm2flexible |
For mounting on | 35 mm DIN rail acc. to EN 60715 | 35 mm DIN rail acc. to EN 60715 | 35 mm DIN rail acc. to EN 60715 | 35 mm DIN rail acc. to EN 60715 | 35 mm DIN rail acc. to EN 60715 | 35 mm DIN rail acc. to EN 60715 | 35 mm DIN rail acc. to EN 60715 | 35 mm DIN rail acc. to EN 60715 |
Enclosure material | red thermoplastic, UL 94 V-0 | thermoplastic, red, UL 94 V-0 | thermoplastic, red, UL 94 V-0 | thermoplastic, red, UL 94 V-0 | thermoplastic, red, UL 94 V-0 | thermoplastic, red, UL 94 V-0 | thermoplastic, red, UL 94 V-0 | thermoplastic, red, UL 94 V-0 |
Degree of protection | IP 20 | IP 20 | IP 20 | IP 20 | IP 20 | IP 20 | IP 20 | IP 20 |
Dimension | 1 mod., DIN 43 | 1 mod., DIN 43 | 1 mod., DIN 43 | 1 mod., DIN 43 | 1 mod., DIN 43 | 1 mod., DIN 43 | 1 mod., DIN 43 | 1 mod., DIN 43 |
Approvals, Certifications | -- | KEMA, VDE, UL, CSA | KEMA, VDE, UL, VdS, CSA | KEMA, VDE, UL, VdS, CSA | KEMA, VDE, UL, VdS, CSA | KEMA, VDE, UL, VdS, CSA | KEMA, VDE, UL, VdS, CSA | KEMA, VDE, UL, VdS, CSA |
Type of remote signalling contact | changeover contact | changeover contact | changeover contact | changeover contact | changeover contact | changeover contact | changeover contact | changeover contact |
Switching capacity a.c. | 250 V/0.5 A | 250 V/0.5 A | 250 V/0.5 A | 250 V/0.5 A | 250 V/0.5 A | 250 V/0.5 A | 250 V/0.5 A | 250 V/0.5 A |
Switching capacity d.c. | 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A | 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A | 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A | 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A | 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A | 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A | 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A | 250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A |
Cross-sectional area for remote signalling terminals | max. 1.5 mm2solid/flexible | max. 1.5 mm2solid/flexible | max. 1.5 mm2solid/flexible | max. 1.5 mm2solid/flexible | max. 1.5 mm2solid/flexible | max. 1.5 mm2solid/flexible | max. 1.5 mm2solid/flexible | max. 1.5 mm2solid/flexible |
1 pcs. | 1 pcs. | 1 pcs. | 1 pcs. | 1 pcs. | 1 pcs. | 1 pcs. | 1 pcs. | |
ordering information | ||||||||
Type | DG S 48 FM | DG S 75 FM | DG S 150 FM | DG S 275 FM | DG S 320 FM | DG S 385 FM | DG S 440 FM | DG S 600 FM |
Part No. | 952 098 | 952 091 | 952 092 | 952 090 | 952 093 | 952 094 | 952 095 | 952 096 |
Packing unit | 1 pc(s) |