Lightning Protection Products

DEHNventil M TN 255(FM)


Product No:Pro200963162427
Product Model:DEHNventil M TN 255(FM)
UpdateTime:
Views:1062

Details


DEHNventil M TN 255(FM)

                    
DEHNventil M TN (FM)               Dimension drawing DV M TN 255 (FM)    Basic circuit diagram DV M TN 255 FM 

DEHNventil M TN 255(FM): Modular combined lightning current and surge arrester for use in single-phase TN systems

  DV M TN 255  DV M TN 255 FM 
SPD according to EN 61643-11 Type 1  Type 1 
SPD according to IEC 61643-1 Class I  Class I 
Energy-coordinated protection effect with regard to the terminal equipment Type 1 + Type 2  Type 1 + Type 2 
Energy-coordinated protection effect with regard to the terminal equipment (≤ 5m) Type 1 + Type 2 + Type 3  Type 1 + Type 2 + Type 3 
Nominal a.c. voltage     [UN] 230 V  230 V 
Max. continuous operating a.c. voltage     [UC] 255 V  255 V 
Lightning impulse current (10/350 µs) [L+N-PE]     [Itotal] 50 kA  50 kA 
Lightning impulse current (10/350 µs) [L,N-PE]     [Iimp] 25 kA  25 kA 
Nominal discharge current (8/20 µs)     [In] 25 / 50 kA  25 / 50 kA 
Voltage protection level [L-PE]     [UP] ≤ 1.5 kV  ≤ 1.5 kV 
Voltage protection level [N-PE]     [UP] ≤ 1.5 kV  ≤ 1.5 kV 
Follow current extinguishing capability a.c.     [Ifi] 50 kArms  50 kArms 
Follow current limitation/Selectivity no tripping of a 20 A gL/gG fuse up to 50 kArms (prosp.)  no tripping of a 20 A gL/gG fuse up to 50 kArms (prosp.) 
Response time     [tA] ≤ 100 ns  ≤ 100 ns 
Max. backup fuse (L) up to IK = 50 kArms 315 A gL/gG  315 A gL/gG 
Max. backup fuse (L) for IK > 50 kArms 200 A gL/gG  200 A gL/gG 
Max. back-up fuse (L) up to IK = 25 kArms A gL/gG  A gL/gG 
Max. back-up fuse (L) up to IK = 25 kArms A gL/gG  A gL/gG 
Max. backup fuse (L-L´) 125 A gL/gG  125 A gL/gG 
Temporary overvoltage (TOV) [L-N]     [UT] 440 V / 5 sec.  440 V / 5 sec. 
Operating temperature range (parallel connection)     [TUP] -40°C...+80°C  -40°C...+80°C 
Operating temperature range (series connection)     [TUS] -40°C...+60°C  -40°C...+60°C 
Operating state/fault indication green / red  green / red 
Cross-sectional area (L, L, N, N, PE, )     [min.] 10 mm2 solid/flexible  10 mm2 solid/flexible 
Cross-sectional area (L, N, PE)     [max.] 50 mm2 stranded/35 mm2 flexible  50 mm2 stranded/35 mm2 flexible 
Cross-sectional area (L, N, )     [max.] 35 mm2 stranded/25 mm2 flexible  35 mm2 stranded/25 mm2 flexible 
For mounting on 35 mm DIN rail acc. to EN 60715  35 mm DIN rail acc. to EN 60715 
Enclosure material red thermoplastic, UL 94 V-0  red thermoplastic, UL 94 V-0 
Degree of protection IP 20  IP 20 
Dimension 4 mods., DIN 4  4 mods., DIN 4 
Approvals, Certifications KEMA, VDE, UL, VdS  KEMA, VDE, UL, VdS 
Type of remote signalling contact --   changeover contact 
Switching capacity a.c. --   250 V/0.5 A 
Switching capacity d.c. --   250 V/0.1 A; 125 V/0.2 A; 75 V/0.5 A 
Cross-sectional area for remote signalling terminals --   max. 1.5 mm2 solid/flexible 
PU 1 pcs.  1 pcs. 
ordering information  
Type DV M TN 255  DV M TN 255 FM 
Part No. 951 200 951 205